Starter, Full Voltage, NEMA Size 0, Open, 120 Volt AC Coil, Eutectic Alloy Overload Relay
A compact design that is ideal when space is at a premium. Allen-Bradley Bulletin 509 NEMA enclosed non-combination non-reversing starters offer provide motor control and overload protection. And they require a separate disconnection means for the branch circuit protection. Catalog item 509-AOD from Rockwell Automation is a NEMA enclosed non-reversing starter.Allen-Bradley is a trademark of Rockwell Automation, Inc.

  • Manufacturer: Allen-Bradley

Specifications

  • Number of indicator lights: 0
  • Voltage type for actuating: AC
  • With transformer: No
  • Suitable for emergency stop: Yes
  • External reset possible: Yes
  • With short-circuit release: Yes
  • With fuse: No
  • Rated control supply voltage at AC 50 Hz: 110 V
  • Rated control supply voltage at AC 60 Hz: 120 V
  • Release class: CLASS 30
  • Type of motor starter: Direct online starter (DOL)
  • Service limit current rating: 21 A
  • Continuous current: 18 A
  • Circuit closing inrush current peak including offset, max: 140 A
  • Heat dissipation: 5.9 W
  • Coil operating limits: 85...110%
  • Operating volt amperes burden: Sealed: 29VA, 60 Hz coils
  • Hp rating, max: 5 Hp @ 575V load voltage, 3-phase (non-plugging and non-jogging duty)
  • Transformer primary switching kVA rating: 5.2 kVA @ 575V load voltage, 3-phase (inrush current ≤20 times continuous current)
  • Temperature compensated overload protection: Yes
  • Coordination class according to IEC 60947-4-3: Class 2
  • Type of electrical connection of main circuit: Screw connection
  • Type of electrical connection for auxiliary- and control current
  • circuit: Screw connection
  • Rail mounting possible: Yes
  • Number of auxiliary contacts, max: 8
  • Mechanical life operations: 1.0E7
  • Average operating time, pick-up: 21 ms
  • Average operating time, drop-out: 16 ms
  • Required torque on power terminal wire clamps and pressure
  • connectors or lugs: 20 lb.inch
  • Auxiliary contact material: Silver
  • Type of power terminal: Saddle or wire clamps
  • Wire size: For power terminals: 14...10 AWG
  • Enclosure: Open type
  • Power contact material: Silver Alloy
  • Requirements for sizing of wire: All wire rated 167 °F (75 °C) or higher must be sized per the local electrical code for 167 °F (75 °C) wire
  • NEMA size: Size 0
  • Operating temperature: 65 °C
  • Operating position: Vertical
  • Altitude: 10000 feet before derating
  • Overload relay: Eutectic alloy overload relay
  • Corrosion-resistance: All metal parts are treated for corrosion-resistance
$145.80

Original: $485.99

-70%
509-AOD - Allen-Bradley - 18 Amp 120V Volt Starter—

$485.99

$145.80

Product Information

Shipping & Returns

Description

509-AOD - Allen-Bradley 18 Amp 120V Volt Starter

Starter, Full Voltage, NEMA Size 0, Open, 120 Volt AC Coil, Eutectic Alloy Overload Relay
A compact design that is ideal when space is at a premium. Allen-Bradley Bulletin 509 NEMA enclosed non-combination non-reversing starters offer provide motor control and overload protection. And they require a separate disconnection means for the branch circuit protection. Catalog item 509-AOD from Rockwell Automation is a NEMA enclosed non-reversing starter.Allen-Bradley is a trademark of Rockwell Automation, Inc.

  • Manufacturer: Allen-Bradley

Specifications

  • Number of indicator lights: 0
  • Voltage type for actuating: AC
  • With transformer: No
  • Suitable for emergency stop: Yes
  • External reset possible: Yes
  • With short-circuit release: Yes
  • With fuse: No
  • Rated control supply voltage at AC 50 Hz: 110 V
  • Rated control supply voltage at AC 60 Hz: 120 V
  • Release class: CLASS 30
  • Type of motor starter: Direct online starter (DOL)
  • Service limit current rating: 21 A
  • Continuous current: 18 A
  • Circuit closing inrush current peak including offset, max: 140 A
  • Heat dissipation: 5.9 W
  • Coil operating limits: 85...110%
  • Operating volt amperes burden: Sealed: 29VA, 60 Hz coils
  • Hp rating, max: 5 Hp @ 575V load voltage, 3-phase (non-plugging and non-jogging duty)
  • Transformer primary switching kVA rating: 5.2 kVA @ 575V load voltage, 3-phase (inrush current ≤20 times continuous current)
  • Temperature compensated overload protection: Yes
  • Coordination class according to IEC 60947-4-3: Class 2
  • Type of electrical connection of main circuit: Screw connection
  • Type of electrical connection for auxiliary- and control current
  • circuit: Screw connection
  • Rail mounting possible: Yes
  • Number of auxiliary contacts, max: 8
  • Mechanical life operations: 1.0E7
  • Average operating time, pick-up: 21 ms
  • Average operating time, drop-out: 16 ms
  • Required torque on power terminal wire clamps and pressure
  • connectors or lugs: 20 lb.inch
  • Auxiliary contact material: Silver
  • Type of power terminal: Saddle or wire clamps
  • Wire size: For power terminals: 14...10 AWG
  • Enclosure: Open type
  • Power contact material: Silver Alloy
  • Requirements for sizing of wire: All wire rated 167 °F (75 °C) or higher must be sized per the local electrical code for 167 °F (75 °C) wire
  • NEMA size: Size 0
  • Operating temperature: 65 °C
  • Operating position: Vertical
  • Altitude: 10000 feet before derating
  • Overload relay: Eutectic alloy overload relay
  • Corrosion-resistance: All metal parts are treated for corrosion-resistance
509-AOD - Allen-Bradley - 18 Amp 120V Volt Starter | SimplyBreakers.com