🎉 Up to 70% Off Selected ItemsShop Sale
Product image 1
HomeStore

509-COD - Allen-Bradley - 45 Amp 120V Volt Starter

509-COD - Allen-Bradley - 45 Amp 120V Volt Starter

509-COD - Allen-Bradley 45 Amp 3 Pole 120V Volt Starter

Starter, Full Voltage, NEMA Size 2, 120 Volt AC Coil, Eutectic Alloy, Overload Relay, requires Heaters, Not Supplied, Open
A compact design that is ideal when space is at a premium. Allen-Bradley Bulletin 509 NEMA enclosed non-combination non-reversing starters offer provide motor control and overload protection. And they require a separate disconnection means for the branch circuit protection. Catalog item 509-COD from Rockwell Automation is a NEMA enclosed non-reversing starter.Allen-Bradley is a trademark of Rockwell Automation, Inc.

  • Manufacturer: Allen-Bradley

Specifications

  • Number of indicator lights: 0
  • Voltage type for actuating: AC
  • With transformer: No
  • Suitable for emergency stop: Yes
  • External reset possible: Yes
  • With short-circuit release: Yes
  • With fuse: No
  • Rated control supply voltage at AC 50 Hz: 110 V
  • Rated control supply voltage at AC 60 Hz: 120 V
  • Release class: CLASS 30
  • Type of motor starter: Direct online starter (DOL)
  • Service limit current rating: 52 A
  • Continuous current: 45 A
  • Circuit closing inrush current peak including offset, max: 483 A
  • Heat dissipation: 5.9 W (4...5 poles)
  • Coil operating limits: 85...110% (4...5 poles)
  • Operating volt amperes burden: Sealed: 38VA, 60 Hz coils (4...5 poles)
  • Hp rating, max: 7-1/2 Hp @ 230V load voltage, 1-phase (non-plugging and non-jogging duty)
  • Transformer primary switching kVA rating: 8.9 kVA @ 575V load
  • voltage, 3-phase (inrush current = 20...40 times continuous current)
  • Capacitor switching kVAR: 31 kVAR @ 575V, 3-phase (If maximum available current (at capacitor terminals) is greater than 3000 A, contact your local Rockwell Automation sales office, Allen"‘Bradley distributor, or NEMA ICS-2 standard)
  • Temperature compensated overload protection: Yes
  • Coordination class according to IEC 60947-4-3: Class 2
  • Type of electrical connection of main circuit: Screw connection
  • Type of electrical connection for auxiliary- and control current
  • circuit: Screw connection
  • Rail mounting possible: Yes
  • Number of auxiliary contacts, max: 8
  • Mechanical life operations: 1.0E7
  • Average operating time, pick-up: 27 ms
  • Average operating time, drop-out: 13 ms
  • Required torque on power terminal wire clamps and pressure
  • connectors or lugs: 45 lb.inch
  • Auxiliary contact material: Silver
  • Type of power terminal: Pressure terminals
  • Wire size: For power terminals: 14...4 AWG
  • Enclosure: Open type
  • Power contact material: Silver Alloy
  • Requirements for sizing of wire: All wire rated 167 °F (75 °C) or higher must be sized per the local electrical code for 167 °F (75 °C) wire
  • NEMA size: Size 2
  • Operating temperature: 65 °C
  • Operating position: Vertical
  • Altitude: 10000 feet before derating
  • Overload relay: Eutectic alloy overload relay
  • Corrosion-resistance: All metal parts are treated for corrosion-resistance
$251.10

Original: $836.99

-70%
509-COD - Allen-Bradley - 45 Amp 120V Volt Starter

$836.99

$251.10

Product Information

Shipping & Returns

Description

509-COD - Allen-Bradley 45 Amp 3 Pole 120V Volt Starter

Starter, Full Voltage, NEMA Size 2, 120 Volt AC Coil, Eutectic Alloy, Overload Relay, requires Heaters, Not Supplied, Open
A compact design that is ideal when space is at a premium. Allen-Bradley Bulletin 509 NEMA enclosed non-combination non-reversing starters offer provide motor control and overload protection. And they require a separate disconnection means for the branch circuit protection. Catalog item 509-COD from Rockwell Automation is a NEMA enclosed non-reversing starter.Allen-Bradley is a trademark of Rockwell Automation, Inc.

  • Manufacturer: Allen-Bradley

Specifications

  • Number of indicator lights: 0
  • Voltage type for actuating: AC
  • With transformer: No
  • Suitable for emergency stop: Yes
  • External reset possible: Yes
  • With short-circuit release: Yes
  • With fuse: No
  • Rated control supply voltage at AC 50 Hz: 110 V
  • Rated control supply voltage at AC 60 Hz: 120 V
  • Release class: CLASS 30
  • Type of motor starter: Direct online starter (DOL)
  • Service limit current rating: 52 A
  • Continuous current: 45 A
  • Circuit closing inrush current peak including offset, max: 483 A
  • Heat dissipation: 5.9 W (4...5 poles)
  • Coil operating limits: 85...110% (4...5 poles)
  • Operating volt amperes burden: Sealed: 38VA, 60 Hz coils (4...5 poles)
  • Hp rating, max: 7-1/2 Hp @ 230V load voltage, 1-phase (non-plugging and non-jogging duty)
  • Transformer primary switching kVA rating: 8.9 kVA @ 575V load
  • voltage, 3-phase (inrush current = 20...40 times continuous current)
  • Capacitor switching kVAR: 31 kVAR @ 575V, 3-phase (If maximum available current (at capacitor terminals) is greater than 3000 A, contact your local Rockwell Automation sales office, Allen"‘Bradley distributor, or NEMA ICS-2 standard)
  • Temperature compensated overload protection: Yes
  • Coordination class according to IEC 60947-4-3: Class 2
  • Type of electrical connection of main circuit: Screw connection
  • Type of electrical connection for auxiliary- and control current
  • circuit: Screw connection
  • Rail mounting possible: Yes
  • Number of auxiliary contacts, max: 8
  • Mechanical life operations: 1.0E7
  • Average operating time, pick-up: 27 ms
  • Average operating time, drop-out: 13 ms
  • Required torque on power terminal wire clamps and pressure
  • connectors or lugs: 45 lb.inch
  • Auxiliary contact material: Silver
  • Type of power terminal: Pressure terminals
  • Wire size: For power terminals: 14...4 AWG
  • Enclosure: Open type
  • Power contact material: Silver Alloy
  • Requirements for sizing of wire: All wire rated 167 °F (75 °C) or higher must be sized per the local electrical code for 167 °F (75 °C) wire
  • NEMA size: Size 2
  • Operating temperature: 65 °C
  • Operating position: Vertical
  • Altitude: 10000 feet before derating
  • Overload relay: Eutectic alloy overload relay
  • Corrosion-resistance: All metal parts are treated for corrosion-resistance

You may also like

NEW
Thumbnail 1

808-M1 - Allen-Bradley - Automation Switch

$2,546.24

-70%NEW
Thumbnail 1

100-C23D10 - Allen-Bradley - 23 Amp Contactor

$119.99

$36.00

-70%NEW
Thumbnail 1

100-C12D10 - Allen-Bradley - 12 Amp Contactor

$59.99

$18.00

-70%NEW

N27 - Allen Bradley Overload Heater Element

$22.99

$6.90

-70%NEW

N37 - Allen Bradley Overload Heater Element

$17.49

$5.25

-70%NEW

N32 - Allen Bradley Overload Heater Element

$21.49

$6.45

NEW
Thumbnail 1

836T-T300J - Allen-Bradley - Pressure Control Switch

$608.84

-70%NEW

840-A4 - Allen-Bradley - Float Switch

$2,854.99

$856.50

-70%NEW

100-SB10 - Allen-Bradley - Auxiliary Contact Block

$24.99

$7.50

-70%NEW

100-C23J10 - Allen Bradley 23 Amp Magnetic Contactor

$269.99

$81.00

-70%NEW
Thumbnail 1

104-C12D22 - Allen-Bradley - Contactor

$275.55

$82.67

-70%NEW
Thumbnail 1

104-C09D22 - Allen-Bradley - Contactor

$204.99

$61.50